Texas Journeyman Electrician Course Notes

Study Texas Journeyman Electrician section notes, then jump straight into the guided course or related practice questions without losing your place.

Continue CourseStart PracticePDF downloads available in Pro.
Checking access

Checking Pro access...

Looking for your active Pro access before showing Course Notes. This usually takes just a moment.

Course Notes preview

Unlock Pro for the full per-exam reference guide.

Preview one piece from each section. Pro includes every Course Notes section, summary, key point, common mistake, exam tip, related-question review, and PDF export.

Includes full Course Mode and Course Notes.

Section 11. Definitions, Calculations, Theory, and Plans (7.5%)Preview
More in this section
  • 13 more key points in Pro version
  • 7 more common mistakes in Pro version
  • 7 more exam tips in Pro version
  • 12 more related questions in Pro version

Summary

This section develops practical decisions for 1. Definitions, Calculations, Theory, and Plans (7.5%). Focus on Calculate single-phase and three-phase current; Size for continuous load; Distinguish service feeder and branch circuit; Distinguish grounded grounding and bonding conductors, then apply the governing rule to the facts in each scenario.

Key Points

  • Single-Phase Current: For resistive loads, current (I) is calculated using the formula: I = P / V, where P is power (in watts) and V is voltage (in volts).

Common Mistakes

  • Single-Phase vs. Three-Phase: The formulas are distinct. Use the single-phase formula for resistive loads and the three-phase formula for balanced three-phase loads.

Exam Tips

  • Double-check your calculations for arithmetic errors.
Section 22. Services, Service Equipment, and Separately Derived Systems (11.5%)Preview
More in this section
  • 13 more key points in Pro version
  • 9 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 20 more related questions in Pro version

Summary

This section develops practical decisions for 2. Services, Service Equipment, and Separately Derived Systems (11.5%). Focus on Locate the service disconnect; Apply service-disconnect grouping rules; Bond the grounded conductor at service equipment; Size and connect the grounding electrode conductor, then apply the governing rule to the facts in each scenario.

Key Points

  • Readily Accessible Nearest Point of Entrance: The service disconnect must be easily reachable, typically outside or inside where the service conductors enter.

Common Mistakes

  • Interior vs. Exterior Runs: Interior runs defeat the principle of accessibility; disconnects must be located outside or inside at the entrance point.

Exam Tips

  • Prioritize Accessibility: The primary factor is whether the disconnect is readily accessible.
Section 33. Feeders (4%)Preview
More in this section
  • 7 more key points in Pro version
  • 3 more common mistakes in Pro version
  • 3 more exam tips in Pro version
  • 5 more related questions in Pro version

Summary

This section develops practical decisions for 3. Feeders (4%). Focus on Size feeder conductors; Calculate feeder neutral load; Protect feeder conductors from overcurrent; Supply a separate building with a feeder, then apply the governing rule to the facts in each scenario.

Key Points

  • The feeder conductor size is determined by calculating the total load (125% of the continuous load plus the noncontinuous load).

Common Mistakes

  • The 125% load factor applies to the continuous load, not the noncontinuous load.

Exam Tips

  • Carefully identify the continuous and noncontinuous load components in each scenario.
Section 44. Branch Circuits, Calculations, and Conductors (19%)Preview
More in this section
  • 13 more key points in Pro version
  • 9 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 35 more related questions in Pro version

Summary

This section develops practical decisions for 4. Branch Circuits, Calculations, and Conductors (19%). Focus on Size branch-circuit conductors and protection; Calculate general lighting load; Apply dwelling small-appliance circuit rules; Apply dwelling laundry circuit rules, then apply the governing rule to the facts in each scenario.

Key Points

  • Ampacity must match the served load, accounting for continuous loads with a 125% increase.

Common Mistakes

  • Terminal ratings and adjustment factors can reduce the allowable ampacity of a conductor, requiring a larger conductor size.

Exam Tips

  • Always start with the total load, including the continuous load's 125% adjustment.
Section 55. Wiring Methods and Materials (22.5%)Preview
More in this section
  • 13 more key points in Pro version
  • 9 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 42 more related questions in Pro version

Summary

This section develops practical decisions for 5. Wiring Methods and Materials (22.5%). Focus on Calculate box fill; Calculate raceway fill; Size raceway for conductor pulling; Support nonmetallic-sheathed cable, then apply the governing rule to the facts in each scenario.

Key Points

  • Box fill assigns conductor-volume allowances by conductor size. Each conductor entering and leaving is counted under 314.16 rules, with specified treatment for loops and pigtails.

Common Mistakes

  • 314.16 rules vs. General conductor volume: 314.16 focuses on *counting* conductors, while general volume allowance considers conductor *size* and its occupied space.

Exam Tips

  • Carefully identify all conductors within the box – including those in pigtails and loops.
Section 66. Equipment and Devices (12.5%)Preview
More in this section
  • 12 more key points in Pro version
  • 8 more common mistakes in Pro version
  • 8 more exam tips in Pro version
  • 22 more related questions in Pro version

Summary

This section develops practical decisions for 6. Equipment and Devices (12.5%). Focus on Install receptacles with correct grounding and polarity; Switch ungrounded conductors; Install luminaires near combustible storage; Provide appliance disconnecting means, then apply the governing rule to the facts in each scenario.

Key Points

  • Grounding-type receptacles utilize grounded contacts connected to the Equipment Grounding Conductor (EGC). The grounded conductor is not attached to the receptacle grounding terminal.

Common Mistakes

  • Grounding Contact vs. Receptacle Grounding Terminal: The grounding contact connects to the EGC; the receptacle grounding terminal is solely for the enclosure’s grounding.

Exam Tips

  • Carefully examine the receptacle labeling and markings to confirm the circuit type and grounding configuration.
Section 77. Motors and Generators (6%)Preview
More in this section
  • 11 more key points in Pro version
  • 5 more common mistakes in Pro version
  • 5 more exam tips in Pro version
  • 9 more related questions in Pro version

Summary

This section develops practical decisions for 7. Motors and Generators (6%). Focus on Size motor branch-circuit conductors; Select motor short-circuit and ground-fault protection; Set motor overload protection; Provide a motor disconnect, then apply the governing rule to the facts in each scenario.

Key Points

  • The general rule for sizing single-motor branch conductors is 125 percent of the table full-load current.

Common Mistakes

  • Using nameplate current for conductor sizing is incorrect; always use the table full-load current.

Exam Tips

  • Always start with the table full-load current provided in the scenario.
Section 88. Control Devices and Disconnecting Means (3.5%)Preview
More in this section
  • 7 more key points in Pro version
  • 3 more common mistakes in Pro version
  • 3 more exam tips in Pro version
  • 4 more related questions in Pro version

Summary

This section develops practical decisions for 8. Control Devices and Disconnecting Means (3.5%). Focus on Classify remote-control and signaling circuits; Use a disconnect within sight; Use a lockable disconnecting means; Identify control-circuit conductors and functions, then apply the governing rule to the facts in each scenario.

Key Points

  • Classification is determined by the source's listing and power limits, not solely by nominal voltage.

Common Mistakes

  • Class 1 vs. Class 2: Class 1 circuits rely on a listed source with specific power limitations. Class 2 circuits are classified based on the source's limitations.

Exam Tips

  • Carefully analyze the source listing and its associated power limitations when determining circuit class.
Section 99. Special Occupancies, Equipment, and Conditions (11%)Preview
More in this section
  • 13 more key points in Pro version
  • 9 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 19 more related questions in Pro version

Summary

This section develops practical decisions for 9. Special Occupancies, Equipment, and Conditions (11%). Focus on Classify hazardous locations; Select equipment for a classified location; Apply healthcare patient-care wiring rules; Install emergency systems, then apply the governing rule to the facts in each scenario.

Key Points

  • Combustible Material & Presence: Hazardous location classification begins with identifying the combustible material (gases/vapors, dust, fibers) and the likelihood/duration of its presence.

Common Mistakes

  • Class I vs. Class II vs. Class III: Class I hazards involve flammable gases/vapors, Class II involves combustible dust, and Class III involves ignitible fibers/flyings.

Exam Tips

  • Focus on the *exact* classification criteria – class, group, division, and temperature – when selecting equipment and wiring.
Section 1010. Renewable Energy Systems (2.5%)Preview
More in this section
  • 5 more key points in Pro version
  • 2 more common mistakes in Pro version
  • 2 more exam tips in Pro version
  • 2 more related questions in Pro version

Summary

This section develops practical decisions for 10. Renewable Energy Systems (2.5%). Focus on Size and protect photovoltaic circuits; Provide PV disconnects rapid shutdown and marking; Interconnect distributed energy resources, then apply the governing rule to the facts in each scenario.

Key Points

  • Maximum Circuit Current (Article 690): The foundation of PV circuit sizing, representing the highest current a circuit is expected to carry.

Common Mistakes

  • 690 vs. Inverter Output: 690 defines maximum current, while inverter output is a dynamic value. Always use 690 for sizing.

Exam Tips

  • Focus on the 'maximum current' principle. Always start with Article 690 calculations.