dc dotCreds
Reference guide

Florida HVAC Contractor Course Notes

Study Florida HVAC Contractor section notes, then jump straight into the guided course or related practice questions without losing your place.

Continue CourseStart PracticePDF downloads available in Pro.
Checking access

Checking Pro access...

Looking for your active Pro access before showing Course Notes. This usually takes just a moment.

Course Notes preview

Unlock Pro for the full per-exam reference guide.

Preview one piece from each section. Pro includes every Course Notes section, summary, key point, common mistake, exam tip, related-question review, and PDF export.

Includes full Course Mode and Course Notes.

Section 1Pre-InstallationPreview
More in this section
  • 41 more key points in Pro version
  • 10 more common mistakes in Pro version
  • 21 more exam tips in Pro version
  • 24 more related questions in Pro version

Summary

Pre-Installation — Air A outline weight about 14%; Air B about 12% (official outlines note content-area percentages may vary). High-yield focus: design HVAC and duct systems; recommend equipment or design changes based on cost, efficiency and load; select controls, motors, compressors, pumps and boilers; calculate thermal resistance using R and U factors; calculate and discuss EER/SEER and energy efficiency; perform heating and cooling load calculations; apply psychrometrics, fan curves and pump curves; size refrigerant, water and other piping; plan rigging, structural loads and mechanical equipment placement; read and interpret plans, specifications, symbols and scales; apply Florida energy-code requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Exam snapshot: Florida DBPR currently administers construction examinations as open-book multiple-choice exams through its construction-examination process.

Common Mistakes

  • Avoid: Thermal resistance (R/U) is not the same as airflow resistance/static pressure.

Exam Tips

  • Write the pressure path before calculating.
Section 2Sheet Metal DuctsPreview
More in this section
  • 17 more key points in Pro version
  • 5 more common mistakes in Pro version
  • 11 more exam tips in Pro version
  • 16 more related questions in Pro version

Summary

Sheet Metal Ducts — Air A outline weight about 9%; Air B about 9% (official outlines note content-area percentages may vary). High-yield focus: fabricate kitchen hoods, exhaust ducts and drain pans; fabricate rectangular and round duct; select sheet metal, fiberglass and flex duct; fabricate fittings, seams and locks; line and insulate duct; seal ducts with approved tapes and mastics. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Commercial cooking exhaust is a fire-safety system; fabrication must follow the adopted code, applicable NFPA 96 provisions, listed hood/system instructions and project documents.

Common Mistakes

  • Avoid: Kitchen grease exhaust is not fabricated like ordinary comfort-air duct.

Exam Tips

  • For grease exhaust, think FIRE + GREASE + ACCESS.
Section 3Installation of Refrigeration and HVAC SystemsPreview
More in this section
  • 41 more key points in Pro version
  • 13 more common mistakes in Pro version
  • 27 more exam tips in Pro version
  • 43 more related questions in Pro version

Summary

Installation of Refrigeration and HVAC Systems — Air A outline weight about 23%; Air B about 22% (official outlines note content-area percentages may vary). High-yield focus: install split and packaged air-conditioning systems; install split and packaged heat pumps; install air-cooled and water-cooled systems; install chilled-water and secondary-coolant systems; install cooling towers; install systems across tonnage ranges; install centrifugal and absorption systems; install low/medium/ultra-low temperature refrigeration; install walk-in and reach-in refrigeration; install ventilation, make-up air and kitchen exhaust; install pneumatic and DDC controls; install geothermal systems; perform testing and balancing; apply fire/smoke-control requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Verify the exact equipment, capacity, voltage/phase, clearances and—where applicable—AHRI matched indoor/outdoor combination before installation.

Common Mistakes

  • Avoid: Split = field-connected indoor/outdoor sections; packaged = factory-contained refrigeration assembly.

Exam Tips

  • Specs before piping.
Section 4Installation of Refrigeration and HVAC Equipment ComponentsPreview
More in this section
  • 23 more key points in Pro version
  • 7 more common mistakes in Pro version
  • 15 more exam tips in Pro version
  • 25 more related questions in Pro version

Summary

Installation of Refrigeration and HVAC Equipment Components — Air A outline weight about 14%; Air B about 14% (official outlines note content-area percentages may vary). High-yield focus: install air-cooled and water-cooled condensers; install hermetic, semi-hermetic and centrifugal compressors; install air handlers and evaporators; install expansion devices, receivers and accumulators; install refrigerant piping and accessories; install controls, motors, starters, relays and electrical components; install pumps, boilers and hydronic components; apply wiring, piping, pressure and refrigerant requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Condenser selection and installation must match refrigerant, capacity, design condensing condition, pressure rating and manufacturer data.

Common Mistakes

  • Avoid: Air-cooled fault clues center on airflow/ambient; water-cooled clues center on water flow/temperature/fouling.

Exam Tips

  • Verify rotation before blame.
Section 5Maintenance Analysis of Refrigeration and HVAC SystemsPreview
More in this section
  • 20 more key points in Pro version
  • 6 more common mistakes in Pro version
  • 13 more exam tips in Pro version
  • 15 more related questions in Pro version

Summary

Maintenance Analysis of Refrigeration and HVAC Systems — Air A outline weight about 9%; Air B about 10% (official outlines note content-area percentages may vary). High-yield focus: interpret pressure-enthalpy relationships; read gauges and system pressures; analyze superheat and subcooling; diagnose airflow, refrigerant and electrical faults; use refrigeration and electrical test instruments; evaluate compressors, motors, controls and heat-transfer components; analyze system capacity and operating efficiency. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • On a P-h diagram, the compressor raises pressure and enthalpy by adding work; real compression is not perfectly isentropic.

Common Mistakes

  • Avoid: Throttling is approximately isenthalpic—not compression, not isentropic expansion.

Exam Tips

  • Metering valve: pressure down, h about constant.
Section 6Maintenance Service of Refrigeration and HVAC SystemsPreview
More in this section
  • 23 more key points in Pro version
  • 7 more common mistakes in Pro version
  • 15 more exam tips in Pro version
  • 25 more related questions in Pro version

Summary

Maintenance Service of Refrigeration and HVAC Systems — Air A outline weight about 14%; Air B about 14% (official outlines note content-area percentages may vary). High-yield focus: repair compressors and refrigeration components; recover, evacuate and charge refrigerants; repair leaks and piping; service electrical controls and motors; clean coils, condensers and condensate drains; service air-distribution equipment; apply EPA refrigerant-handling requirements; perform preventive maintenance and component replacement. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Do not condemn a compressor from one symptom; verify electrical supply, mechanical condition, refrigerant pressures, superheat/floodback and heat rejection.

Common Mistakes

  • Avoid: Repairing the failed part is not the same as correcting the cause.

Exam Tips

  • Root cause before replacement.
Section 7Safety and EquipmentPreview
More in this section
  • 17 more key points in Pro version
  • 5 more common mistakes in Pro version
  • 11 more exam tips in Pro version
  • 15 more related questions in Pro version

Summary

Safety and Equipment — Air A outline weight about 9%; Air B about 10% (official outlines note content-area percentages may vary). High-yield focus: apply PPE and job-site safety; use ladders, rigging and lifting equipment safely; handle refrigerants and compressed gases safely; use hand and power tools safely; apply electrical safety and lockout/tagout; apply pressure-vessel and compressed-air safety. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • PPE is the last line of defense after elimination, substitution, engineering and administrative controls; select PPE for the actual hazard.

Common Mistakes

  • Avoid: PPE does not make an otherwise prohibited procedure acceptable.

Exam Tips

  • Hazard first, PPE second.
Section 8Energy ManagementPreview
More in this section
  • 14 more key points in Pro version
  • 4 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 6 more related questions in Pro version

Summary

Energy Management — Air A outline weight about 5%; Air B about 5% (official outlines note content-area percentages may vary). High-yield focus: perform duct pressure and blower-door testing; evaluate building-envelope effects; recommend energy-efficient equipment; perform load and thermal-resistance calculations; apply Florida energy-code requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Duct leakage testing quantifies air leakage of the duct system at a specified pressure under the applicable code/test protocol.

Common Mistakes

  • Avoid: Duct test = air-distribution leakage; blower door = building-envelope leakage.

Exam Tips

  • Define the boundary.
Section 9Indoor Air QualityPreview
More in this section
  • 14 more key points in Pro version
  • 4 more common mistakes in Pro version
  • 9 more exam tips in Pro version
  • 4 more related questions in Pro version

Summary

Indoor Air Quality — Air A outline weight about 3%; Air B about 4% (official outlines note content-area percentages may vary). High-yield focus: select filtration systems; apply UV treatment concepts; manage humidity; select air cleaners; measure and balance airflow. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.

Key Points

  • Filtration efficiency and pressure drop must be considered together; a high-efficiency filter that starves airflow can reduce HVAC performance.

Common Mistakes

  • Avoid: Filter efficiency ≠ whole-system IAQ by itself.

Exam Tips

  • Efficiency + pressure drop.