Section 1Pre-InstallationPreview
More in this section
41 more key points in Pro version
10 more common mistakes in Pro version
21 more exam tips in Pro version
24 more related questions in Pro version
Summary
Pre-Installation — Air A outline weight about 14%; Air B about 12% (official outlines note content-area percentages may vary). High-yield focus: design HVAC and duct systems; recommend equipment or design changes based on cost, efficiency and load; select controls, motors, compressors, pumps and boilers; calculate thermal resistance using R and U factors; calculate and discuss EER/SEER and energy efficiency; perform heating and cooling load calculations; apply psychrometrics, fan curves and pump curves; size refrigerant, water and other piping; plan rigging, structural loads and mechanical equipment placement; read and interpret plans, specifications, symbols and scales; apply Florida energy-code requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Exam snapshot: Florida DBPR currently administers construction examinations as open-book multiple-choice exams through its construction-examination process.
Common Mistakes
Avoid: Thermal resistance (R/U) is not the same as airflow resistance/static pressure.
Exam Tips
Write the pressure path before calculating.
Section 2Sheet Metal DuctsPreview
More in this section
17 more key points in Pro version
5 more common mistakes in Pro version
11 more exam tips in Pro version
16 more related questions in Pro version
Summary
Sheet Metal Ducts — Air A outline weight about 9%; Air B about 9% (official outlines note content-area percentages may vary). High-yield focus: fabricate kitchen hoods, exhaust ducts and drain pans; fabricate rectangular and round duct; select sheet metal, fiberglass and flex duct; fabricate fittings, seams and locks; line and insulate duct; seal ducts with approved tapes and mastics. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Commercial cooking exhaust is a fire-safety system; fabrication must follow the adopted code, applicable NFPA 96 provisions, listed hood/system instructions and project documents.
Common Mistakes
Avoid: Kitchen grease exhaust is not fabricated like ordinary comfort-air duct.
Exam Tips
For grease exhaust, think FIRE + GREASE + ACCESS.
Section 3Installation of Refrigeration and HVAC SystemsPreview
More in this section
41 more key points in Pro version
13 more common mistakes in Pro version
27 more exam tips in Pro version
43 more related questions in Pro version
Summary
Installation of Refrigeration and HVAC Systems — Air A outline weight about 23%; Air B about 22% (official outlines note content-area percentages may vary). High-yield focus: install split and packaged air-conditioning systems; install split and packaged heat pumps; install air-cooled and water-cooled systems; install chilled-water and secondary-coolant systems; install cooling towers; install systems across tonnage ranges; install centrifugal and absorption systems; install low/medium/ultra-low temperature refrigeration; install walk-in and reach-in refrigeration; install ventilation, make-up air and kitchen exhaust; install pneumatic and DDC controls; install geothermal systems; perform testing and balancing; apply fire/smoke-control requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Verify the exact equipment, capacity, voltage/phase, clearances and—where applicable—AHRI matched indoor/outdoor combination before installation.
Section 4Installation of Refrigeration and HVAC Equipment ComponentsPreview
More in this section
23 more key points in Pro version
7 more common mistakes in Pro version
15 more exam tips in Pro version
25 more related questions in Pro version
Summary
Installation of Refrigeration and HVAC Equipment Components — Air A outline weight about 14%; Air B about 14% (official outlines note content-area percentages may vary). High-yield focus: install air-cooled and water-cooled condensers; install hermetic, semi-hermetic and centrifugal compressors; install air handlers and evaporators; install expansion devices, receivers and accumulators; install refrigerant piping and accessories; install controls, motors, starters, relays and electrical components; install pumps, boilers and hydronic components; apply wiring, piping, pressure and refrigerant requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Condenser selection and installation must match refrigerant, capacity, design condensing condition, pressure rating and manufacturer data.
Common Mistakes
Avoid: Air-cooled fault clues center on airflow/ambient; water-cooled clues center on water flow/temperature/fouling.
Exam Tips
Verify rotation before blame.
Section 5Maintenance Analysis of Refrigeration and HVAC SystemsPreview
More in this section
20 more key points in Pro version
6 more common mistakes in Pro version
13 more exam tips in Pro version
15 more related questions in Pro version
Summary
Maintenance Analysis of Refrigeration and HVAC Systems — Air A outline weight about 9%; Air B about 10% (official outlines note content-area percentages may vary). High-yield focus: interpret pressure-enthalpy relationships; read gauges and system pressures; analyze superheat and subcooling; diagnose airflow, refrigerant and electrical faults; use refrigeration and electrical test instruments; evaluate compressors, motors, controls and heat-transfer components; analyze system capacity and operating efficiency. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
On a P-h diagram, the compressor raises pressure and enthalpy by adding work; real compression is not perfectly isentropic.
Common Mistakes
Avoid: Throttling is approximately isenthalpic—not compression, not isentropic expansion.
Exam Tips
Metering valve: pressure down, h about constant.
Section 6Maintenance Service of Refrigeration and HVAC SystemsPreview
More in this section
23 more key points in Pro version
7 more common mistakes in Pro version
15 more exam tips in Pro version
25 more related questions in Pro version
Summary
Maintenance Service of Refrigeration and HVAC Systems — Air A outline weight about 14%; Air B about 14% (official outlines note content-area percentages may vary). High-yield focus: repair compressors and refrigeration components; recover, evacuate and charge refrigerants; repair leaks and piping; service electrical controls and motors; clean coils, condensers and condensate drains; service air-distribution equipment; apply EPA refrigerant-handling requirements; perform preventive maintenance and component replacement. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Do not condemn a compressor from one symptom; verify electrical supply, mechanical condition, refrigerant pressures, superheat/floodback and heat rejection.
Common Mistakes
Avoid: Repairing the failed part is not the same as correcting the cause.
Exam Tips
Root cause before replacement.
Section 7Safety and EquipmentPreview
More in this section
17 more key points in Pro version
5 more common mistakes in Pro version
11 more exam tips in Pro version
15 more related questions in Pro version
Summary
Safety and Equipment — Air A outline weight about 9%; Air B about 10% (official outlines note content-area percentages may vary). High-yield focus: apply PPE and job-site safety; use ladders, rigging and lifting equipment safely; handle refrigerants and compressed gases safely; use hand and power tools safely; apply electrical safety and lockout/tagout; apply pressure-vessel and compressed-air safety. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
PPE is the last line of defense after elimination, substitution, engineering and administrative controls; select PPE for the actual hazard.
Common Mistakes
Avoid: PPE does not make an otherwise prohibited procedure acceptable.
Exam Tips
Hazard first, PPE second.
Section 8Energy ManagementPreview
More in this section
14 more key points in Pro version
4 more common mistakes in Pro version
9 more exam tips in Pro version
6 more related questions in Pro version
Summary
Energy Management — Air A outline weight about 5%; Air B about 5% (official outlines note content-area percentages may vary). High-yield focus: perform duct pressure and blower-door testing; evaluate building-envelope effects; recommend energy-efficient equipment; perform load and thermal-resistance calculations; apply Florida energy-code requirements. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Duct leakage testing quantifies air leakage of the duct system at a specified pressure under the applicable code/test protocol.
Common Mistakes
Avoid: Duct test = air-distribution leakage; blower door = building-envelope leakage.
Exam Tips
Define the boundary.
Section 9Indoor Air QualityPreview
More in this section
14 more key points in Pro version
4 more common mistakes in Pro version
9 more exam tips in Pro version
4 more related questions in Pro version
Summary
Indoor Air Quality — Air A outline weight about 3%; Air B about 4% (official outlines note content-area percentages may vary). High-yield focus: select filtration systems; apply UV treatment concepts; manage humidity; select air cleaners; measure and balance airflow. Use this section as a rapid review; the 200-card study guide carries the deeper application detail.
Key Points
Filtration efficiency and pressure drop must be considered together; a high-efficiency filter that starves airflow can reduce HVAC performance.
Common Mistakes
Avoid: Filter efficiency ≠ whole-system IAQ by itself.
Exam Tips
Efficiency + pressure drop.